Three-Level Inverter Technology: Peak efficiency ≥98.5%, standby loss ≤0.5%, overall energy efficiency improved by 20% compared to traditional solutions.
Wide Voltage Input: Supports 600–950Vdc DC input from fuel cells, compatible with PEM, ALK, and other technologies.
Stable Full-Condition Operation: 100% three-phase unbalanced load capacity, voltage fluctuation ≤1%, THDi ≤3%, compliant with IEEE 1547 grid-connection standards.
Fully Sealed Protection Design: Critical components fully potted, IP55 protection rating, resistant to salt spray, dust, high altitude (≤5000m), and extreme temperatures.
Plug-and-Play: Supports hot-swappable modules. Single-unit power: 125kW–625kW; parallel expansion up to 5MW without downtime.
Compact & High Density: Power density up to 1.4kW/L, 35% smaller size, saving 40% installation space.
Multi-Mode Operation: Seamless grid-connected/off-grid switching, supports constant power, voltage, and frequency control, adaptable to microgrid dispatch requirements.
Cloud Connectivity: Built-in RS485/Ethernet interfaces, supports Modbus and CAN protocols, integrates with Energy Management Systems (EMS) for remote monitoring and efficiency optimization.
⇒ Product Parameter
Product |
Power module |
Power cabinet |
|
Number of built-in power modules |
\ |
N(N≤6) |
|
AC grid connection parameters |
Input Voltage Range |
600-950 V |
|
Maximum Input Current |
210 A |
N×210 A |
|
Rated output power |
125kW |
N×125kW |
|
Maximum Power |
110% |
||
DC voltage |
400V |
||
Permissible |
-20%~+15% |
||
Permissible grid fluctuation range |
±10% |
||
Power factor range |
1.0 leading~1.0 lagging |
||
Current harmonic |
≤3%(linear load) |
||
AC off-grid parameters |
Rated output power |
125kW |
N×125kW |
Maximum Power |
110% |
||
Grid voltage |
400V |
||
Rated grid frequency |
50/60Hz |
||
Voltage harmonic |
≤3% (linear load) |
||
Highest efficiency |
98.50% |
||
Access method |
3P3L+PE / 3P34+PE |
||
General |
Dimensions |
440×600×130 |
600×850×2000 |
Protection level |
IP20 , IP54 |
||
Temperature range |
-35~60℃ |
||
Humidity range |
0~95% No condensation |
||
Cooling method |
Intelligent air-cooled |
||
Process interlocking |
Including |
||
Communication interface |
RS485, Modbus RTU, Modbus TCP |
||
Human-computer |
10-inch touch screen interaction |
||
Inport and outport |
Up in /Down out |