1000 SCM Large Capacity Electrolyser power supply for PEM
Designed for PEM type electrolysers, better adapted to high current densities.
External step-down transformer for frequency isolation and higher efficiency.
DC Harmonic ≤ 3%,power factor ≥ 0.99.
DC voltage ripple ≤ 1%
Intelligent liquid cooling will effectively improve the life of devices and the whole equipment
IP54 protection for better adaptation to complex environments
Unique P/I curve setting function
Full-power regulation response time ≤ 100ms
Product model :
HRP1000PProduct parameters :
1000Precision Compatibility: Custom-designed for the low-voltage, high-current characteristics of PEM electrolyzers, supporting millisecond-level dynamic power adjustment to seamlessly adapt to fluctuating renewable energy inputs.
IP54 Protection: Fully sealed dustproof and waterproof design, resistant to high humidity, salt spray, and dust, ideal for coastal, desert, and industrial environments.
High Power Density: Advanced IGBT devices paired with a liquid-cooled heat dissipation system achieve 1.5kW/L power density, reducing size by 50% compared to traditional solutions.
Ultimate Efficiency: Maximum efficiency ≥97.5%, with overall energy consumption reduced by 20%.
Clean Power Output: Power factor ≥0.99, current harmonic distortion (THD) ≤0.5%, compliant with IEEE 519 standards—no additional filtering required.
Smart Energy Feedback: Supports reactive power compensation and energy feedback functions, alleviating grid load pressure.
P/I Adaptive Output: Proprietary power-current regulation algorithm dynamically optimizes electrolyzer operation, limiting hydrogen output fluctuations to <2%.
Full-Chain Monitoring: Built-in high-precision sensors and diagnostic system enable remote emergency shutdown and data traceability.
⇒ Product Parameter
product |
HRP1000P |
||
hydrogen yield (m³/h) |
1000 |
||
AC input parameters |
AC voltage range |
400~600V ac |
|
Permissible grid voltage range |
±10% |
||
Rated grid frequency |
50/60Hz |
||
Permissible grid frequency range |
±10% |
||
Power Factor |
≥0.99 |
||
Power factor range |
0.9 leading~0.9 lagging |
||
Current harmonic distortion |
≤3% |
||
Access method |
3P3L + PE |
||
DC output parameters |
Output Power |
5000kW |
|
Maximum Power |
110% maximum output |
||
Maximum DC current (A) |
12000 |
||
Maximum DC voltage (V) |
900 |
||
Current range |
0~Maximum output current |
||
Voltage range |
0~Maximum output voltage |
||
Current ripple |
≤1%-Ipp |
||
Current accuracy |
≤0.5%×maximum current |
||
Dynamic response |
≤100ms, slope can be set |
||
Control method |
Constant current control |
||
General |
Highest efficiency |
97.50% |
|
Dimensions (W×D×H mm) |
2720×1865×2305 |
||
Protection level |
IP54 |
||
Temperature range |
-35~60℃ |
||
Humidity range |
0~95% No condensation |
||
Fault recording and broadcasting diagnosis |
Including |
||
Process interlocking |
Including |
||
Communication interface |
RS485, Modbus RTU, Modbus TCP |
||
Human-computer interaction interface |
10-inch touch screen interaction |
||
Inport and outport |
Up in /Down out |